ORDER OF THE GOVERNMENT OF THE REPUBLIC OF KAZAKHSTAN

of July 31, 2014 No. 863

About approval of the qualification requirements imposed to non-state fire services

According to the subitem 51) of article 11 of the Law of the Republic of Kazakhstan of April 11, 2014 "About civil protection" the Government of the Republic of Kazakhstan DECIDES:

1. Approve the enclosed qualification requirements imposed to non-state fire services.

2. This resolution becomes effective after twenty one calendar days after day of its first official publication.

Prime Minister of the Republic of Kazakhstan

K. Masimov

Approved by the Order of the Government of the Republic of Kazakhstan of July 31, 2014 No. 863

The qualification requirements imposed to non-state fire services

1. These qualification requirements imposed to non-state fire services (further - qualification requirements) are developed for the purpose of determination of compliance of non-state fire services on performance of works according to the prevention and suppression of the fires, carrying out wrecking in the organizations, settlements and on objects of the Republic of Kazakhstan.

2. The following qualification requirements are imposed to non-state fire services:

1) availability at least one fire the truck of the basic purpose confirmed with the technical inspection report of its readiness for suppression of the fires according to appendix 1 to these qualification requirements *;

2) availability of the building or room for accommodation of workers, the rescue and fire fighting equipment, the equipment and equipment *;

3) availability of the staff employees provided with special regimentals and fire-proof equipment on the regulations established for bodies of the public fire service according to appendix 2 to these qualification requirements, number:

at least 16 people, at the rate of the 4th worker including the driver on each main fire truck during duty shift *;

at least 8 people, at the rate of the 2nd worker during duty shift **;

4) compliance of workers of non-state fire services of the qualification specified in appendix 3 to these qualification requirements.

Note:

* - for non-state fire services with the exit fire fighting equipment;

** - for non-state fire services without the exit fire fighting equipment.

Appendix 1

to the Qualification requirements imposed to non-state fire services

Act * technical inspection of readiness of the main fire truck for suppression of the fires

_____________________________________________________________________
(name NGPS)

Brand, the __________ model on the ___________ chassis year of release ____________

registration registration plate ______________ owner _______________

________________ chassis body ______________ ________________ engine

1. Availability and maintaining the form of the car No. ________, the registration certificate of the vehicle No. ______ from ______, the certificate on passing of technical inspection

___________________________________________________________________

2. Run on speedometer __________ km.

3. The inventory and availability of fire technical equipment and equipment on the car:

 

payment order

Name of the equipment and equipment

Unit of measure

Quantity

Availability (is available / is absent)

1

2

3

4

5

1

The sleeve which is soaking up, 4 m long with a diameter of 125 mm

piece.

2

 

2

The sleeve which is soaking up, 4 m long with a diameter of 75 mm

piece.

2

 

3

The sleeve is pressure head, for work from hydrant, 4 - 5 m long with a diameter of 77 mm

piece.

2

 

4

The sleeve is pressure head, 20 m long with a diameter of 66 mm

piece.

10

 

5

The sleeve is pressure head, 20 m long with a diameter of 51 mm

piece.

6

 

6

The sleeve which is soaking up, 4 m long with a diameter of 30 mm

piece.

1

 

7

Grid for soaking-up CB-125, sleeve with rope 12 m long

piece.

1

 

8

Branching 3-tradable RT - 70 (RT - 80)

piece.

2

 

9

Catchment basin hose AF - 125 with caps

piece.

1

 

10

Key face for opening of hydrants

piece.

1

 

Warning!!!

This is not a full text of document! Document shown in Demo mode!

If you have active License, please Login, or get License for Full Access.

With Full access you can get: full text of document, original text of document in Russian, attachments (if exist) and see History and Statistics of your work.

Get License for Full Access Now

Disclaimer! This text was translated by AI translator and is not a valid juridical document. No warranty. No claim. More info

Effectively work with search system

Database include more 50000 documents. You can find needed documents using search system. For effective work you can mix any on documents parameters: country, documents type, date range, teams or tags.
More about search system

Get help

If you cannot find the required document, or you do not know where to begin, go to Help section.

In this section, we’ve tried to describe in detail the features and capabilities of the system, as well as the most effective techniques for working with the database.

You also may open the section Frequently asked questions. This section provides answers to questions set by users.

Search engine created by SojuzPravoInform LLC. UI/UX design by Intelliants.